Ensure that the generator circuit breaker (circled in blue in image below) is OFF and the Voltage selector is in the -> 120V/240V position.
There is a pigtail made-up to connect the generator to the clothes drier outlet.
Danger
Always Ensure that the Main Circuit Breaker is OFF And that the Generator Circuit Breaker is OFF before connecting or
disconnecting the pigtail to the house or generator.
Connect the pigtail to the generator (the plug twists clockwise to lock - circled in yellow below) and to the clothes drier outlet. see images below.
Ensure the fuel valve is turned to the on position.
Crank engine to start. Use of the Choke may be required.
Allow the engine to warm up for 3-5 minutes.
8. Turn on GENERATOR CIRCUIT BREAKER. Observe for overload condition. If generator overloads (bogs down) turn off generator breaker and remove some loads.
Repeat until generator is not overloaded.